Fan heater or cooler control
Electric or water-supplied fan heaters / coolers are typically used in logistics, production halls or sports facilities to heat or cool the air. Fan speed can be controlled manually or demand-based. Temperature-based control increases comfort and delivers significant energy savings.
Show filters
Hide filters
Filtered result
EC fan heater controller | Wi-Fi and LAN gateway
Industrial fan heater controller with cloud connection. EC fan speed is regulated manually or automatically. The higher the difference between the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. Via the separate internet gateway connection with SenteraWeb is possible. SenteraWeb is the online cloud platform for monitoring, data logging, remote access, day-week scheduler, etc. The controller can be connected via the local Wi-Fi network or via the LAN gateway.
Articles
Logical controller for heating/cooling applications with EC-fans, temperature input: PT500, analogue output: 0-10 VDC, relay output: CO, Imax: 10 A.
Power supply module, supply voltage: 85-264 VAC/ 50-60 Hz, output voltage: 24 VDC / 40 VA, IP65, Power over Modbus (PoM) compatible.
Internet Gateway in IP54 plastic enclosure, supply voltage: 24 VDC PoM (Power over Modbus), RTU Modbus communication with master/slave channel, integrated Ethernet LAN and WiFi-connection, version: 2.
Flying lead temperature probe, stainless steel tube 53 (L) x 8 (D) mm, PTC 500 Ω, 4 m unshielded cable, 2 x 0,5 mm².
Current stock 0 U.
Factory lead time 4 Week(s)
Next arrival 06/12/2024 - 10 U.
Article has been added to your shopping cart.
EC fan heater controller | Wi-Fi gateway
Industrial fan heater controller with cloud connection. EC fan speed is regulated manually or automatically. The higher the difference between the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. Via the separate internet gateway connection with SenteraWeb is possible. SenteraWeb is the online cloud platform for monitoring, data logging, remote access, day-week scheduler, etc. The controller can be connected via the local Wi-Fi network.
Articles
Logical controller for heating/cooling applications with EC-fans, temperature input: PT500, analogue output: 0-10 VDC, relay output: CO, Imax: 10 A.
Power supply module, supply voltage: 85-264 VAC/ 50-60 Hz, output voltage: 24 VDC / 40 VA, IP65, Power over Modbus (PoM) compatible.
Internet gateway in IP65 plastic enclosure, supply voltage: 24 VDC PoM (Power over Modbus), RTU Modbus communication, integrated WiFi-connection.
Flying lead temperature probe, stainless steel tube 53 (L) x 8 (D) mm, PTC 500 Ω, 4 m unshielded cable, 2 x 0,5 mm².
Modbus RTU (RS485) adapter from three RJ45 (8-pins) to 4-pin terminal block.
Current stock 0 U.
Factory lead time 5 Week(s)
Next arrival 06/12/2024 - 10 U.
Article has been added to your shopping cart.
EC fan heater and cooler controller
Industrial fan heater controller to heat warehouses or manufacturing plants. This controller regulates fan speed and controls an external water valve. The higher the difference between
the measured temperature value and the temperature setpoint, the higher the EC fan speed. The unregulated output controls a water valve or an electric heating element. All parameters can be adjusted via Modbus RTU communication.
Articles
Logical controller for heating/cooling applications with EC-fans, temperature input: PT500, analogue output: 0-10 VDC, relay output: CO, Imax: 10 A.
Flying lead temperature probe, stainless steel tube 53 (L) x 8 (D) mm, PTC 500 Ω, 4 m unshielded cable, 2 x 0,5 mm².
Current stock 0 U.
Factory lead time 4 Week(s)
Next arrival 06/12/2024 - 10 U.
Article has been added to your shopping cart.
Heater controller | AC motor 2,5 A
5-speed controller for fan heaters with single phase motor. The maximum motor current is 2,5 A. AC fan speed is regulated manually or automatically. When the temperature drops below the set point, the hot water valve is opened via the unregulated output. This unregulated output can control a water valve or an electric heating element. Ambient temperature is measured. The higher the difference between the measured temperature value and the temperature setpoint, the higher AC fan speed. The fan speed is controlled in 5-steps.
Articles
Transformer fan speed controller with switched heating control output, supply voltage: 230 VAC ±10 % / 50-60 Hz, Imax: 2,5 A, 5 steps in manual mode 0-80-110-140-170-230 VAC, auto mode depending on temperature setpoint.
Flying lead temperature probe, stainless steel tube 53 (L) x 8 (D) mm, PTC 500 Ω, 4 m unshielded cable, 2 x 0,5 mm².
Current stock 0 U.
Factory lead time 4 Week(s)
Next arrival 06/12/2024 - 10 U.
Article has been added to your shopping cart.
Heater controller | AC motor 5 A
5-speed controller for fan heaters with single phase motor. The maximum motor current is 5 A. AC fan speed is regulated manually or automatically. When the temperature drops below the set point, the hot water valve is opened via the unregulated output. This unregulated output can control a water valve or an electric heating element. Ambient temperature is measured. The higher the difference between the measured temperature value and the temperature setpoint, the higher AC fan speed. The fan speed is controlled in 5-steps.
Articles
Transformer fan speed controller with switched heating control output, supply voltage: 230 VAC ±10 % / 50-60 Hz, Imax: 5 A, 5 steps in manual mode 0-80-110-140-170-230 VAC, auto mode depending on temperature setpoint.
Flying lead temperature probe, stainless steel tube 53 (L) x 8 (D) mm, PTC 500 Ω, 4 m unshielded cable, 2 x 0,5 mm².
Current stock 0 U.
Factory lead time 4 Week(s)
Next arrival 06/12/2024 - 10 U.