Product description
Monitoring device for differential pressure over an air filter. When the air filters of the ventilation system need to be replaced, an automatic notification message is sent to one or multiple users.
FIM series connect via an ethernet cable or via the local Wi-Fi network to SenteraWeb - the online HVAC portal. The built-in differential pressure sensor monitors the evolution of the pressure over the air filter. When the air filter gets polluted, differential pressure increases. When a threshold value is exceeded, an automatic notification message is sent via email or SMS message by SenteraWeb. Based on this notification, you are notified in time that the air filter needs to be replaced soon. Maintenance and air filter replacement can be scheduled ahead.
The LEDs on the front cover provide a visual indication. The enclosure can be mounted on a panel or wall nearby the air filter.
Documents
Additional specifications and description
Clean air filters for good indoor air quality
A ventilation system supplies the building with filtered, fresh air. The air filters of the ventilation system stop pollen, dust particles and other contaminants. To achieve a healthy indoor air climate, air filters must be cleaned or replaced on a regular basis. Sometimes this is forgotten or done much too late with serious consequences for indoor air quality. After all, polluted air filters cannot not stop all pollutants any longer. In addition to good indoor air quality, another benefit of clean air filters is the fact that they allow the airflow to pass through more easily. This means: a significantly lower energy consumption of the fans. How quickly an air filter becomes dirty depends on many different parameters as well as on local conditions. It is therefore not easy to estimate when it needs to be cleaned or replaced. Best is to measure the degree of pollution of the air filters via the FIM filter monitoring unit. When they need to be cleaned or replaced, a notification is sent via email or SMS message. This makes it possible to schedule maintenance in advance and to organize it efficiently.
Differential pressure as a measure of pollution
As the air filters become dirty, more and more particles accumulate in the air filter. This makes it more difficult for the airflow to pass through the air filter. This increases the differential pressure over the air filter. The FIM air filter monitor measures the differential pressure over the air filter. When the threshold value is exceeded, a notification is sent that the air filters require maintenance. The LEDs on the front panel provide a visual indication. In case of a clean air filter, the LED is green. When the pollution increases, the color of the LED changes to yellow. When the filter is heavily contaminated and the differential pressure exceeds the threshold value, the LED turns red.
Notification message to replace air filters
FIM air filter monitors are connected to SenteraWeb - the online HVAC portal. Via SenteraWeb it is possible to view connected devices, log data, change settings (e.g. differential pressure threshold value) or receive notifications. FIM -EW versions require an ethernet cable (LAN network) or the local Wi-Fi network to connect to SenteraWeb. For each air filter monitor, different users and configurators can be defined. A user can see the differential pressure over the air filter and check the status. Users cannot change settings. Configurators can also change settings (e.g. threshold value for differential pressure alert). Configurators can activate data logging to follow the evolution of differential pressure over the air filter. Logged data can be exported (.csv file). Notifications can be sent via email or via a text message (SMS) to the selected users and configurators.